Reverse Osmosis System 8000 GPD With Vertical Multistage Pump (Chinese Big Unit)

Reverse Osmosis System 8000 GPD With Vertical Multistage Pump (Chinese Big Unit)

R55,000.00

Qty:
Compare
SKU: RO8000HORC Category:

Description

Features

  • Sediment Filter: 5 Micron Sediment Filter that removes sediments and protects the system.
  • High Pressure Pump: 1HP Motor Vertical Multi-Stage Pump with flow rate of 1080 Litres/H. High quality stainless steel Shimge Pump for long-life usage.
  • RO Membrane: One of the industry’s leading brackish water RO elements – Vontron-4040. Membrane Housing: 4″ x 40″ Stainless Steel Housing with 300PSI maximum operating pressure.
  • Pressure Gauges: Glycerin Filled Gauges for monitoring the system’s operating pressure and per litre operating pressures.
  • Low Pressure Switch: Safety device to protect the pump from running dry when there is insufficient water feed pressure.
  • Solenoid Valves: To assist with the on/off functionality of the system and automatic membrane flush.
  • Flow Meters: One Product and One Waste Flow Meters – Enables operator to actually adjust product to waste ratio and monitor system’s performance.
  • Regulator Valve: One Stainless Steel ANSI 316 Needle Valve – regulates the product to waste ratio (system’s recovery).
  • Micro-Computer Controller: A specialised controller designed by Puritech for commercial systems with automatic controls and TDS monitors.

OPTIONAL FEATURES:

  • Stainless Steel Components: ANSI 304 and 316 can be used with solenoid valves and pumps for brackish water treatment.
  • Concentrate Re-Circulation
  • Automatic Pre-treatment Systems
  • Chemical Dosing Pumps

SPECIFICATION

  • Capacity: 6000 GPD
  • RO Membrane: 4 pcs
  • RO Pump: 3HP
  • Voltage/Hertz: 110V or 220V / 50Hz or 60Hz / Single phase or three phase
  • Pipe Size: 3/4″ Feed, 1/2″ Permeate, 1/2″ Concentrate, 1/2″ Flush (BSP thread)

OPERATING PARAMETERS

  • 180 PSI | Max. Feed TDS | 1000 ppm
  • Normal Salt Rejection: 99% | Max. Feed Hardness | 15 ppm
  • Minimum Salt Rejection: 96% | Feed pH Range | 3.0 – 10.0 ppm
  • Operating Temperature: 20 ̊C – 45 ̊C | Free Residual Chlorine | 0.1 ppm
  • Minimum Feed Pressure: 1.5Kg | Recovery Rate | 60% – 75%

* Minimum recovery rate is calculated based on no concentrate recirculation, it is possible to increase the overall recovery rate by increasing the concentrate circulation flow.

** Permeate flow rate can vary depending on type of membrane, raw water quality, and recovery rate.

Reviews

There are no reviews yet.

Be the first to review “Reverse Osmosis System 8000 GPD With Vertical Multistage Pump (Chinese Big Unit)”

Your email address will not be published. Required fields are marked *

X