4000 LPH RO System

R227,700.00

Out of stock

Compare
SKU: RO4000LPH Category:

Description

PLEASE NOTE!

When you consider purchasing this system, you need to know the following information as it is very important.

This system requires a pretreatment setup for it to perform like it was designed to.

Below, the sketch shows a basic pretreatment setup with the reverse osmosis system.


The above pretreatment setup is not guaranteed to work unless recommended by a sales agent according to the water analysis report from a lab.

A water analysis report is very important as it determines the pretreatment setup needed to be installed before the reverse osmosis system. As you can see on the sketch above, the pretreatment consists of a Sand/Glass Filter, Carbon Filter, and Antiscalant Dosing system.

Pretreatment setups can consist of even more items installed before the reverse osmosis system. Below is a list of items that could be required as per the water analysis report.

  1. Chlorine Dosing System
  2. Ultrafiltration System
  3. Dmi-65 Iron Removal Media Filter System
  4. Ozone Generator
  5. Flocculant System

Once all the equipment has been purchased, you will need a qualified technician to put together the complete setup. We have our own qualified technicians train by the manufacturers of the equipment to do the installation running of the setup. Should you require us to install the system for you, a quote with the installation fee will be sent to you by the sales agent in charge.

Training can also be offered to the guys you want to be the ones installing your setup instead of our technicians.

Industrial Reverse osmosis pure water filtration systems technology is the most advanced and energy-saving membrane separation technology. The main working principle is to remove dissolved salt, colloid, microbial organisms under the action of osmosis pressure. As the RO membrane aperture is very small (only 10A), so other material cannot pass through a semi-permeable membrane.
The solute is retained on the pressurized side of the membrane and the pure solvent is allowed to pass to the RO membrane. This membrane should not allow large molecules or ions through the pores but should allow smaller components of the solution (such as solvent molecules) to pass the RO membrane.
The pumps used in industrial reverse osmosis water filtration systems include Shimge and CNP pumps that have passed ISO9001 quality system certification, ISO14001 environmental management system certification, CE certification, and material is stainless steel so as to prevent rust and pressure. This product is widely used in the food industry, such as juice, milk tea, infusion and cleaning for hospitals, etc.

Product Advantages

  1. RO membrane‘s aperture is very small
  2. Easy installation
  3. The most advanced and energy-saving membrane separation technology

Function

Item Function
precision filter prevent large particles, bacteria, viruses into RO membrane, accuracy is 5um
High-pressure pump Provide the high pressure to RO membrane
RO system the main part of the plant. The RO membrane’s desalting rate can reach 99%, removing over 99% of ions
UV sterilizer kill bacteria

Description

Capacity 4000LPH/24000GPD
Voltage 220V/50Hz,220V/60Hz, Single phase
Recovery 50%-70%
Desalination 96%-99%
Membrane Qty 2pcs
Temp of raw water 1-45℃
Feed Water Pressure 1-5 bar
Raw water TDS 0-1000ppm
Application raw water Tap water, Brackish water, Seawater
RO Membrane Vontron, Dow
Item name Material
Pressure gauge assembly
HP PUMP SS304
RO Membrane housing FRP
Pure Flowmeter Plexiglas Panel
waste Flowmeter Plexiglas Panel
Conductivity meter engineering plastics
Pressure switch brass
 inlet valve brass
flush valve brass
Regulating valve brass
UV sterilizer SS304
Electronic control system air switch.electric relay.alternating current contractor.switch.LED
control box SS304 /Mild Steel
Frame SUS304
pipeline UPVC 3/4”