RUNXIN F65P3 Automatic Softener Valve

R1,932.00

Out of stock

Compare
SKU: F65P3 Category:

Description

 

RUNXIN F65P3 Automatic Softener Valve

RUNXIN F65P3 Automatic Softener Valve – RUNXIN F65P3 Automatic Softner 3/4″ pipe 2.5″ opening/ 2(m3/H) Volume Regeneration

Technical Parameters:

  • Water Pressure: 0.15—0.6MPa
  • Water Temperature: 5℃-50℃
  • Transformer Output: DC12V、1.5A
  • Water Turbidity: Down-flow regeneration<5FTU
  • Inlet/Outlet: 3/4″F
  • Drain: 1/2″M
  • Brine Line Connector: 3/8″M
  • Base: -2.5″-8NPSM
  • Riser Pipe: 1.05 ″OD
  • Max Flow Rate: -2 m3/h
  • Suitable Tank Size (in): 6″~12″

Product Characteristics:

  • More reliable open/close way
  • Long-term outage indicates
  • Interlock function
  • Icon lock function
  • Mainboard and display board integrate, no need wirings, easy to after-sales.
  • Optocoupler locate, simple and makes locating board universal

 

F65P Automatic Multiport Softener Valves

The flow rate of the F65P automatic multiport softener valve is 2m³/h. It is a simple softening valve that adopts a planar and corrosion-resistant gasket for opening and closing. Service, backwash, brine and slow rinse, brine refill, and fast rinse functions can be realized through parameter modifications. The F65P1 is a timer clock type while F65P3 is a meter type.

Product Characteristics

  • Simple structure and reliable sealing

    It adopts hermetic head faces with high pottery and corrosion resistance for opening and closing. It combines with Service, Backwash, Brine & Slow Rinse, Brine Refill and Fast Rinse for softener or Service, Backwash and Fast Rinse for the filter.

  • No water passes the valve in regeneration in the single tank type
  • Manual function

    Realize regeneration immediately by pressing ” Manual/Return” at any time.

  • Long outage indicator

    If an outage overrides 3 days, the time of day indicator “12:12” will flash to remind the people to reset the new time of day. The other set of parameters does not need to be reset. The process will continue to work after the power is on.

  • The valve will automatically rotate for dozens of seconds after it is electrified

    After the valve is electrified, it will automatically rotate for dozens of seconds to turn back to the position when the electricity is cut off.

  • Buttons lock

    No operations to buttons on the controller within 1 minute, button lock indicator lights on which represent buttons are locked. Before the operation, press and hold the “ Up” and “Down” buttons for 5 seconds to unlock. This function can avoid incorrect operation.

  • Interval backwash times (Suitable for F68P/F69P)

    It could set up interval backwash times for F68P/F69P up-flow regeneration valve which means several times of services but one time of backwash. The setting of interval backwash time depends on the local water turbidity. (The lower the turbidity is, the length of the interval backwash time can be set)

  • It can choose a time clock type or meter type by program selection

    When all symbols light on, press and hold Menu/Confirm and Manual/Return buttons for 5 seconds to enter the menu of valve model selection. Please set the program type in accordance with the product type. (Time clock type by days or meter type) (Note: The meter type product has one flow meter and probe wire, but the time clock type doesn’t have one).

  • Maximum interval regeneration days

    Under the situation of service reaching the setting days and the volume not yet, it could enter into the regeneration process forcibly when the current time is the same as the regeneration time.

  • All parameters can be modified

    According to the water quality and usage, the parameters in the process can be adjusted.